Dashboard

The following table shows the main dashboard configuration parameters. Buttons and push rotary can be configured by clicking on them.

Parameter Name

Parameter Range

Parameter Definition

Button

Not Available

The NCP105 has 4 programmable buttons. You can program each button by clicking them on the dashboard menu. The programming is no different than creating a widget.

 

Up to 8 layers can be created and programmed in the NCP105. You can select NCP105(SELF) as the device and change the active layer. The first layer has the number 0.

Rotary

Not Available

The NCP105 has a single push rotary button. You can program it by clicking them on the dashboard menu. The programming is no different than creating a widget.

Assigning the volume function of a zone also yields the mute/unmute function by pushing.

Plus Icon

Not Available

Up to 8 layers can be created and programmed in the NCP105 by clicking the plus icon.

Bin Icon

Not Available

Unwanted layers can be deleted using the bin icon.

Save Button

Not Available

The save button will be highlighted in green after every change in the configuration of the NCP105.

The 360 LED indicator should spin in white after pressing the save button.

The following table shows the actions available for volume in the input block and mixer channels in the zone block.

Parameter Name

Parameter Range

Parameter Definition

Up

Not Available

Increases the volume.

Down

Not Available

Decreases the volume.

Fixed

Not Available

Sets the volume value to a desired value.

The following table shows the actions available for mute in the input block and mixer channels in the zone block.

Parameter Name

Parameter Range

Parameter Definition

Toggle

Not Available

Toggles between mute and unmute.

Fixed

Not Available

Sets the value to the desired value, mute or unmute.

The following table shows the actions available for the route in the mixer of the zone block. You can cycle up, down or go to a fixed source, one of the 16 mapped sources to a zone. When the source is routed, the routed source gets the 0dB value on the mixer where the rest is set to -90dB. It is also possible to add one of the eight scenes to that cycle or fixed value. In addition, you can add Off mode to the cycle.

Parameter Name

Parameter Range

Parameter Definition

Cycle Up

Not Available

Increases the volume.

Cycle Down

Not Available

Decreases the volume.

Fixed

Not Available

Sets the volume value to a desired value.
Example NCP105 Configuration

In this example, you can configure your NCP105 to control Zone 1 and Zone 2 volumes and sources using 4 layers. Buttons will have the same function in each layer but the rotary functions will be changed in every layer.

in all four layers. The rotary button will be,

Device Settings

Device Name

Parameter Name

Parameter Range

Parameter Definition

Full Name

Not Available

Full name is used on the drop-down selection lists and in the Dante Controller for Dante channels.

 

Full name is also used as device/Bluetooth name on the NWP series.

 

Short Name

Not Available

Short is used on the overview screen channel labels
Version

Parameter Name

Parameter Range

Parameter Definition

Firmware Version

Not Available

Indicates the installed firmware version.

Build Number

Not Available

Indicates the build number of the installed firmware version.

Update Firmware

Not Available

The available firmware version can be installed here. The latest and previous versions are both available. Using the latest AUDAC Touch version and firmware is highly recommended to get the most out of your Atellio family devices.

When a new firmware version is available, the button will be highlighted in orange.

Network Settings

Parameter Name

Parameter Range

Parameter Definition

DHCP

Enable/Disable

Switch between dynamic or static IP

MAC

Not Available

MAC address of the device

IP

Not Available

The IP address of the device can be set here when DHCP is disabled (e.g. 192.168.20.170)

Mask

Not Available

The subnet mask can be set here (e.g. 255.255.255.0)

Gateway

Not Available

The gateway IP address can be set here for the devices that act as the bridge for the network traffic like the network switch (e.g. 192.168.20.1)

DNS1/DNS2

Not Available

The primary and secondary/alternative DNS addresses can be set here (e.g. 1.1.1.1)
Device Address

Parameter Name

Parameter Range

Parameter Definition

Index

Enable/Disable

You can set a unique number to the device in a scenario where you have more than one of the same device.

Time Settings (Only for the LUNA series)

It is important to configure the time settings correctly. This is needed for the event handler time trigger to work correctly.

Parameter Name

Parameter Range

Parameter Definition

Time Zone

Not Available

GMT zone can be selected based on country names

Server Address

Not Available

The NTP server IP address can be set in this line

Finding an NTP Server 
If your network has any restrictions, it is recommended to contact your network management to obtain the NTP address for the network you are connecting to, if the network is unmanaged or has no port restrictions then to find the IP address relative to you simply ping the address as shown below.


"europe.pool.ntp.org"
"asia.pool.ntp.org"
"oceania.pool.ntp.org"
"north-america.pool.ntp.org"
"south-america.pool.ntp.org"
"africa.pool.ntp.org"
 

Target Device Settings (Only for NPM200)

Up to 20 devices can be set as target devices for paging and voice file announcements for a single NPM200. Please refer to "Target Devices Settings" for a detailed explanation.

Button Sensitivity (Only for NCP105)

Parameter Name

Parameter Range

Parameter Definition

Button Sensitivity

0-100

The sensitivity of programmable buttons can be set individually.

Physical Button Functions (Only for the NWP series)

Parameter Name

Parameter Range

Parameter Definition

Bluetooth Pairing

Enable/Disable

Enable or disable the Bluetooth pairing function using the button on the NWP series devices.

Mic/Line Mode

Enable/Disable

Enable or disable the mic/line level switch function using the button on the NWP series devices.

Factory Reset

Enable/Disable

Enable or disable the factory reset function using the push rotary button on the NWP series devices.

Top